BT 1500

The BT1500 is small in size but big in performance. The BT1500 can run both clinical chemistry and turbidimetric tests.
The BT1500 is equipped with a bar-code reader for identification of samples and reagents and can be programmed to run up to 250 tests per hour in random, batch, and STAT test modes.
With an excellent on-board washing system and on-board cooling, the BT1500 can accommodate 48 reagents and a total of 78 samples, i.e., 62 patient samples and 16 standards or controls, and can be programmed with 3 level controls (3 known and 3 unknown).
The Excellent Washing mechanism is designed to prevent carryover and maintain the 32 optical glass cuvettes in their optimal state.

Categories: ,

TECHNICAL SPECIFICATIONS

Throughput

Up to 250 tests per hour

ISE module on board

Not available

Number of Reagents

48 Total: 24 using 50-ml vessel; 24 using 10 or 20-ml vessel

Refrigerated reagent bay

Yes

Reaction volume

From 180 to 400 µl

Reading Cuvettes

32 non-disposable optical glass

Sample volume

From 1,8 to 100 µl

Sampling Arms

1 for Serum and Reagents

Sample tray # of position

78 Total: 62 Samples and 16 Standards and Controls

Test Modes

Random Access, Batch, and STAT

Test Directory

Up to 500

Cevette temperature control

Peltier System OFF/30/32/37°C (±0,2°C)

Photometer

Solid State 10 Channel + reference channel

Photometer accuracy

± 1% (0-2 O.D.), + 2,5% (2-3 O.D.)

Photometer sensitivity

± 0,001 Abs

Diluter

1: Long-life ceramic, 340 µl

Diluter precision

± 0,1% f.s.

Diluter resolution

0,1 µl

Bar Code

Optional, both for Reagents and Samples

Computer

External PC: optional; see PC minimum requirements below

Pheripherals

Optional, on request, printer and UPS

Process electronics

7 microcontroller. I² CBUS Protocol

Interface

USB 2.0 to PC

Built-in QC Program

Yes, 3 Levels Known, 3 Level Unknown

Maintenance

Software Assisted

Power Supply

Universal Input: 100/240 Volts, 50-60 Hz, 300 Watt, PFC

U.P.S.

1000 Watt (optional)

Dimension

Height: 51 cm (20), width: 78 cm (30.7″), depth: 58 cm (22.8″)

Weight

53 Kg (116 lb)

clot sensor

Not available

Peso

53 Kg

EXTERNAL PC MINIMUM REQUIREMENTS FOR BT 1500

Operative System

Windows 2000 Professional
Windows XP
Windows Vista (32-bit) and Windows 7 (32-bit)

Computer

IBM compatible

Processor

Pentium dual-core duo

Ram

1 GB (2 GB for Windows Vista)

Video

SVGA or compatible, 32K colors

Mouse

Serial, PS2 or USB, 2+1 button

Host Communication

RS232 or LAN (TCP/IP)

USB

1, version 2.0 for communication with the analyzer

Parallel port

1, if the printer has a parallel port

Printer

Windows-compatible Deskjet, Inkjet or Laser
The printer must be installed on the PC before installing the operating software

CD ROM

DVD reader

HD

5Gb free